Fujifilm -Clinica X (OTC & FS) – MavenImaging
 

Fujifilm -Clinica X (OTC & FS)

Scalable, high-quality, cost-effective x-ray solution Achieve diagnostic clarity and operational efficiency with the Clinica X (OTC & FS). Built upon a foundation of Fujifilm’s extensive history in imaging innovation, this system provides radiologists and technicians with the tools necessary for...
Need a quote? Get an instant quote delivered to your email!
We value your privacy and will not sell your information to anyone.

Product Details

Scalable, high-quality, cost-effective x-ray solution

Achieve diagnostic clarity and operational efficiency with the Clinica X (OTC & FS). Built upon a foundation of Fujifilm’s extensive history in imaging innovation, this system provides radiologists and technicians with the tools necessary for precise, confident diagnoses. The system significantly reduces the need for retakes and manual adjustments by automating the optimization of every scan, ensuring that critical anatomical details are visible from the very first exposure.

At the core of the FDR Clinica X is Fujifilm’s proprietary Irradiated Side Sampling (ISS) technology. Conventional detectors typically position capture electronics on the back of the panel, which can lead to signal loss as X-rays pass through the scintillator layer. In contrast, the FDR Clinica X places its Thin-Film Transistors (TFTs) directly on the irradiation side. This strategic design suppresses the scattering and attenuation of X-ray signals, allowing the system to capture information with greater efficiency and fidelity.

Advanced Image Processing Technology

The core of the Clinica X performance is Fujifilm’s proprietary Dynamic Visualization II. This intelligent processing engine goes beyond standard image capture; it analyzes the specific anatomic characteristics within the exposure field to adjust contrast and density in real-time. By recognizing the difference between bone, soft tissue, and empty space, the system harmonizes the image to present a balanced, high-fidelity view of the patient's condition.

  • Intelligent Feature Recognition: The system identifies specific anatomical structures to automatically optimize clarity and contrast throughout the entire exposure field, reducing the workload for technicians.
  • Enhanced PACS Flexibility: Users experience greater window and leveling capabilities within their Picture Archiving and Communication System (PACS), allowing for more detailed post-capture analysis.
  • Superior First-Up Images: Dynamic Visualization II delivers images with outstanding detail immediately upon capture, streamlining the workflow and speeding up patient throughput.

Patented ISS capture technology

The FDR Clinica X (OTC & FS) represents a significant leap forward in digital radiography, engineered to deliver exceptional diagnostic clarity while prioritizing patient safety. This system integrates advanced detection capabilities to overcome the limitations of traditional X-ray designs, ensuring medical professionals have access to the most precise data possible for accurate diagnoses.

  • High Sensitivity: Patented ISS capture technology promotes high sensitivity, ensuring that the detector captures the maximum amount of useful signal from every exposure.
  • Sharper Image Quality: By minimizing signal scatter, the system produces images with superior sharpness and detail. This clarity is crucial for identifying subtle pathologies that might be missed with standard equipment.
  • Lower Dose Efficiency: The enhanced efficiency of the detector design allows for high-quality imaging at lower X-ray doses compared to conventional designs. This reduction in radiation exposure supports better patient care and safety protocols.
  • Proven Technology: The system's ability to improve image quality through higher Modulation Transfer Function (MTF) and Detective Quantum Efficiency (DQE) is supported by research into the effects of X-ray incident direction and scintillator layer design.

 

 

 

 

 

 

 



 

 

 

 

 

 

 

Product Reviews

Shipping & Returns

Shipping - Delivery shall be made at FOB shipping point of origin. Seller's responsibilities for the Equipment purchased pursuant hereto ceases and title and risk of loss passes to Customer upon delivery to the carrier. In the event of loss, damage, injury or destruction after such delivery to the carrier, claims must be made against the carrier and not against Seller. In no event shall any loss, damage, injury or destruction operate in any manner to release Customer from the obligation to make payments required herein. Returns - Unless a product is labeled "all sales final" at the time of purchase, all orders may be returned within 30 days for a refund. In order to return or exchange (under the guidelines described below) all or part of your order, customer must contact us for a Return Merchandise Authorization number (RMA#). Call toll free (800) 949-8015 to obtain RMA # from a Seller's representative. All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. with the authorization (RMA#) clearly printed on the outside of the package. Return requests must be made within 30 days of the receipt date. All returns must be certified to be in good condition by one of our engineers before refund can be accepted. If the product has been damaged, seller will assess the damage and will determine if the product is entitled to a refund. All free items must be returned together with purchased items in order to receive a refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levy a restocking fee of 25% of the cost of items returned. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied. Installation, training or professional services are NON-REFUNDABLE. Seller is responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal US Postal Service cannot be tracked to ensure delivery. Since Seller cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.