FUJI FDR AQRO with FDR ES – MavenImaging
 

FUJI FDR AQRO with FDR ES

FDR AQRO with FDR ES FUJIFILM's next-generation mobile X-ray solution. The FDR AQRO offers a compact and light-weight digital X-ray system with ultra-high sensitivity and mobility for simple, easy handling in any radiographic situation. The articulating control panel allows rotation,...
Need a quote? Get an instant quote delivered to your email!
Please enter your name.
Please valid email address.
Please company name.
Please enter valid phone number.
We value your privacy and will not sell your information to anyone.

Product Details

FDR AQRO with FDR ES

FUJIFILM's next-generation mobile X-ray solution. The FDR AQRO offers a compact and light-weight digital X-ray system with ultra-high sensitivity and mobility for simple, easy handling in any radiographic situation. The articulating control panel allows rotation, tilting and height adjustment for procedure setting and instant image confirmation from any angle. Convenient on-board FDR ES detector charging and storage bin tilts for applying a protective cover. The high-performance Li-ion battery power enables up to 12-hours of continuous use at 20-exposures/hour and rapid charging of 4-hours for a full charge. Additionally, a 15-minute Quick Charge provides up to 1-hour or 20-exposures. Designed with cleanliness in mind, the FDR AQRO utilizes Fujifilm's exclusive Hydro AG antibacterial coating on the primary surface areas and has a flat, cordless body design for easy wipe down.

 

Technologist Console:

  • Performs patient ID, image processing, QA, Worklist updates and image transmission
  • Simplified user interface for complete exam processing in as few as 2-3 steps.
  • Speed Link X-ray Control Software automates exposure techniques to exam menus
  • QC adjustments: exam reprocessing, sensitivity, latitude, density and contrast
  • Advanced Image Processing: Virtual Grid and Dynamic Visualization II
  • Portables Exam Tools: image mag, double-click full-screen zoom, edge enhancement toggle, automatic trimming for offset imaging, shuttering (black borders), movable annotation markers & text annotation and more.

X-ray Generator:

  • Maximum Power Output 2.5kW
  • Tube voltage  40−100 kV
  • Tube Current Max 35 mA

 

X-ray Tube:

  • Focal Spot Size: 1.2 mm
  • Target Angle: 16 degrees
  • Anode Heat Capacity: 50kHU (35kJ)

 

Tube Head Movement:

  • SID to Floor:   78.7”– 14.6”
  • Tube Arm Reach: 34.2”
  • Arm Rotation Range: +/- 15 degrees
  • Tube Rotation Angle: +/- 165 degrees
  • Tube Tilt: -40 to +180 degrees

 

Physical Characteristics:

  • 23.6” W x 33.5” L
  • Height: 57.5” (collapsed); 82.5” (extended)
  • Weight: 90kg (198lbs.)

 

 

FDR ES 14C All Wireless Package

FDR ES All-Wireless packages create a cord-free environment in the x-ray room.

 

  • Model name: FDR ES 14C
  • 14x17 fits standard Buckys, 6.4 lbs.
  • CsI: Cesium Iodide scintillator with ISS capture
  • Image Preview in less than 2 seconds, less than 10 second cycle time.
  • 150 Micron Pixel Pitch (2836x2336 pixel matrix)
  • Wireless meets HIPAA requirements for secure patient data transmission

 

Panel Batteries and Charging:

  • Includes 3 batteries and 1 battery charger (2 slots, 3.6”x 10.2”x 2.2”; 1.3 lbs.)
  • Each charge lasts up to 200 continuous exposures
  • Recharge to full in 3 hours max, 3-minute charge provides up to 30 exposures

 

Accessories Included:

  • Accessory Case
  • (1) Wipes Holder
  • (1) Lead Apron Hanger

Download Data Sheet

 

Product Reviews

Shipping & Returns

Shipping - Delivery shall be made at FOB shipping point of origin. Seller's responsibilities for the Equipment purchased pursuant hereto ceases and title and risk of loss passes to Customer upon delivery to the carrier. In the event of loss, damage, injury or destruction after such delivery to the carrier, claims must be made against the carrier and not against Seller. In no event shall any loss, damage, injury or destruction operate in any manner to release Customer from the obligation to make payments required herein. Returns - Unless a product is labeled "all sales final" at the time of purchase, all orders may be returned within 30 days for a refund. In order to return or exchange (under the guidelines described below) all or part of your order, customer must contact us for a Return Merchandise Authorization number (RMA#). Call toll free (800) 949-8015 to obtain RMA # from a Seller's representative. All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. with the authorization (RMA#) clearly printed on the outside of the package. Return requests must be made within 30 days of the receipt date. All returns must be certified to be in good condition by one of our engineers before refund can be accepted. If the product has been damaged, seller will assess the damage and will determine if the product is entitled to a refund. All free items must be returned together with purchased items in order to receive a refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levy a restocking fee of 25% of the cost of items returned. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied. Installation, training or professional services are NON-REFUNDABLE. Seller is responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal US Postal Service cannot be tracked to ensure delivery. Since Seller cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.