POINT OF CARE HAND-CARRIED ULTRASOUND SYSTEM
Simple Needle Visualization
Contrary to traditional beam-steering methods, SONIMAGE HS2 employs an algorithm that employs two methods— in-plane and out-plane— to enhance needle imaging, particularly crucial in steep-angle approaches. This innovation portrays the needle tip without requiring the ultrasound probe to be perfectly perpendicular to the needle, which might not always be feasible due to patient positioning constraints or challenging clinical conditions. This enhanced visibility of the needle facilitates efficient procedures.
Contrary to traditional beam-steering methods, SONIMAGE HS2 employs an algorithm that employs two methods— in-plane and out-plane— to enhance needle imaging, particularly crucial in steep-angle approaches. This innovation portrays the needle tip without requiring the ultrasound probe to be perfectly perpendicular to the needle, which might not always be feasible due to patient positioning constraints or challenging clinical conditions. This enhanced visibility of the needle facilitates efficient procedures.
Flow Pixel Counter (FPC)
The Flow Pixel Counter (FPC) serves as a tool for quantifying the proportion of blood flow signals within a designated region of interest (ROI) in 2D-mode. It offers a valuable means to determine the ratio of a specific ROI area to the presence of blood flow signals, making it particularly useful in assessing new blood vessel formations within tumors or inflammation of the synovial membrane in rheumatoid patients.
High-Resolution Probe
Featuring the top-of-the-line L18-4 linear transducer, this probe delivers exceptional image quality necessary for visualizing deep tissues such as muscles, tendons, and nerves in musculoskeletal evaluations or pain management procedures. Its unique lightweight design ensures superior image clarity, enhancing clinical confidence during examinations.
Ergonomic Design
Designed with a sharp focus on ergonomics, usability, and adaptability, the SONIMAGE HS2 is versatile for various healthcare settings—it seamlessly transitions from cart to desktop use.
Workflow Efficiency
With its sleek, compact design and user-friendly interface, the SONIMAGE HS2 optimizes data distribution and offers exceptional economic value across different healthcare settings, from clinics to bedside examinations. Its seamless connectivity through DICOM to ImagePilot or other information systems provides a range of workflow options, catering to current needs and accommodating future growth.
The Flow Pixel Counter (FPC) serves as a tool for quantifying the proportion of blood flow signals within a designated region of interest (ROI) in 2D-mode. It offers a valuable means to determine the ratio of a specific ROI area to the presence of blood flow signals, making it particularly useful in assessing new blood vessel formations within tumors or inflammation of the synovial membrane in rheumatoid patients.
High-Resolution Probe
Featuring the top-of-the-line L18-4 linear transducer, this probe delivers exceptional image quality necessary for visualizing deep tissues such as muscles, tendons, and nerves in musculoskeletal evaluations or pain management procedures. Its unique lightweight design ensures superior image clarity, enhancing clinical confidence during examinations.
Ergonomic Design
Designed with a sharp focus on ergonomics, usability, and adaptability, the SONIMAGE HS2 is versatile for various healthcare settings—it seamlessly transitions from cart to desktop use.
Workflow Efficiency
With its sleek, compact design and user-friendly interface, the SONIMAGE HS2 optimizes data distribution and offers exceptional economic value across different healthcare settings, from clinics to bedside examinations. Its seamless connectivity through DICOM to ImagePilot or other information systems provides a range of workflow options, catering to current needs and accommodating future growth.
Main Unit Specifications
Warranty: 5 years
Mode: B, M, Color, Power, PWD
Monitor: 15 inch IPS type monitor
Dimensions (folded monitor): W 369 x D 452 x H 90
Power Supply: AC100 – 240V max 180 VA
Weight: 17.2 lbs (including battery )
Probe SpecificationsType: Linear probe L18-4 (optional to L14-4)
Bandwidth: 4 - 18 MHz
Probe Specifications
Product Reviews
Shipping & Returns
Shipping - Delivery shall be made at FOB shipping point of origin. Seller's responsibilities for the Equipment purchased pursuant hereto ceases and title and risk of loss passes to Customer upon delivery to the carrier. In the event of loss, damage, injury or destruction after such delivery to the carrier, claims must be made against the carrier and not against Seller. In no event shall any loss, damage, injury or destruction operate in any manner to release Customer from the obligation to make payments required herein.
Returns - Unless a product is labeled "all sales final" at the time of purchase, all orders may be returned within 30 days for a refund. In order to return or exchange (under the guidelines described below) all or part of your order, customer must contact us for a Return Merchandise Authorization number (RMA#). Call toll free (800) 949-8015 to obtain RMA # from a Seller's representative. All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. with the authorization (RMA#) clearly printed on the outside of the package. Return requests must be made within 30 days of the receipt date. All returns must be certified to be in good condition by one of our engineers before refund can be accepted. If the product has been damaged, seller will assess the damage and will determine if the product is entitled to a refund. All free items must be returned together with purchased items in order to receive a refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levy a restocking fee of 25% of the cost of items returned. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied. Installation, training or professional services are NON-REFUNDABLE. Seller is responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal US Postal Service cannot be tracked to ensure delivery. Since Seller cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.