Product Details
GP-6 System, includes Four Way Float Top Table, Non-Rotate
Tube stand, Wall Stand, and 32 kW High-Frequency Generator
SHF 310AP 32 kW, 400 mA, 125 kVp, 500 mAs HF Generator
- 400 mA, 125 kVp (400 mA @ 80 kVp)
- Seventeen mA stations: 10, 12.5, 16, 20, 25, 32, 40,
- 50, 64, 80, 100, 125, 180, 200, 250, 320, 400
- 0.001 to 10 second time range
- 0.1 to 500 mAs
- kVp selection, 40 to 125 kVp in 1 kV increments
- Digital displays
- Automatic line compensation
- APR, Anatomical Programming
- Table mount
- Exposure hand switch
- UL/CE/FDA Listed
- For Operation on 1 Phase 208/240 VAC
Four-Way Float Top Table, Fixed Height, Multirad
- Tabletop dimensions 86.6" x 32.4" (2200mm x 825mm)
- Longitudinal tabletop travel 35" (+/-17.5") (900mm)
- Transverse tabletop travel 9" (+/-4.5") (230mm)
- Tabletop to Film Distance: 4" (102mm)
- Bucky travel: 20.3" (581mm)
- Tabletop to floor distance 30.3" (769mm)
- Electromagnetic brakes
- Bucky table top material in white color plastic laminated
- Full-length footswitch along table base
- • Absorption 0.9 mm al equivalent
- • Heavy-duty grid cabinet
- • Heavy-duty manual cassette tray
- 103 line, 10:1 ratio, 34-44" focal range grid
- The tabletop will support patients up to 300 kgs (661 lbs)
Floor to Wall Non-Rotate Tubestand, Medical
Fits in ceiling heights of 88" - 121"
- Vertical travel 11.75" - 76.75"
- 75.2" Longitudinal Travel with 8' floor track
- 21" tube arm (focal spot to the front of column 23")
- 32.2" focal spot from wall
- Platform tube mount, angulation dial an operator handles
- Manual lock for tube angulation
- Electric lock for longitudinal and vertical travel
- 8-foot tracks
Wall stand with grid cabinet
- Floor to wall mounted counterbalanced column
- Minimum ceiling height: 86" from floor
- Vertical travel: 9-3/4" to 72-3/4"
- Electric locks (24VDC 2 Amp required)
- Grid cabinet with heavy-duty tray
- 10:1, 103 line grid
- Operates on 120 VAC
- UL Classified operates from 24 VDC
Tube, 140,000HU, 1.0-2.0, 90 deg
Certified Manual Collimator with laser light, LED, 125kVP
20 ft HV Cables
WARRANTY: FIVE YEARS ON PARTS. TUBE IS 1ST YEAR FULL, REMAINING FOUR YEARS ARE PRORATED
Patient Image 14x17 Wireless Flat Panel DR System
14 x 17-inch CSI Wireless, cassette size DR Flat Panel Detector, with advanced acquisition Patient Image software and PACS
System Specifications
14x17 inch CSI Wireless, cassette size DR Flat Panel Detector
- Active area (Real Image Size):
- 360x430 (14x17 inches)
- Overall Dimensions: 344x459x15 mm (13.5x18x0.59 inches)
- Weight: 3.8 +/- 0.25 Kg
- Power Consumption: Idle - 3.3 watts, Acquisition - 7.8 watts, Image Transfer - 10.2 watts
- Pixel Pitch: 139 μ m
- Pixel Matrix Size: 3,052 (v) x 2,456 (h)
- A/D Conversion: 16 bit
- X-ray Voltage Range: 40-150 kVp
- Wireless Modes STA or AP: 802.11 a/g/n/ac, 2x2 MIMO
- 2 Batteries, Battery Charger, and Back-up Cable Included
- Automatic Parameter Selection
- Specific Anatomical Post-processing
Patient Imaging Acquisition Software and Mini Pacs
10 Viewer license
Dell Precision 3430 Small Form Factor (Min. Configuration):
- Intel Core i5-8500, 5 Core, 9MB Cache, 3.0GHz, 4.1Ghz Turbo w/
- HD Graphics 630
- Windows 10 Professional
- 1 TB Hard Disk
- 8 GB RAM
- 24 inch Monitor
Workstation pre-configured and with the Software installed
On-site Installation
Training
Maven Imaging Sample Urgent Care room Layout
*This product has been permanently discontinued.
Replacement products available.