Product Details
GP-5 System includes Four Way Float Top Table, Rotate Tubestand, Wall Stand, and 40 kW High-Frequency Generator
SHF 410AP 40 kW, 500 mA, 125 kVp, 500 mAs HF Generator
- 500 mA., 125 kVp (500 mA. @ 80 kVp)
- Eighteen mA stations: 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500
- 0.001 to 10 second timing
- 0.1 to 500 mAs
- kVp selection, 40 to 125 kVp in 1 kV increments
- Digital displays
- Automatic line compensation
- APR, Anatomical Programming
- Table mount
- Exposure hand switch
- UL/CE/FDA Listed
- For Operation on 1 Phase 208/240 VAC
Four-Way Float Top Table, Fixed Height, Multirad
- Tabletop dimensions 86.6" x 32.4" (2200mm x 825mm)
- Longitudinal tabletop travel 35" (+/-17.5") (900mm)
- Transverse tabletop travel 9" (+/-4.5") (230mm)
- Tabletop to Film Distance: 4" (102mm)
- Bucky travel: 20.3" (581mm)
- Tabletop to floor distance 30.3" (769mm)
- Electromagnetic brakes
- Bucky table top material in white color plastic laminated • Full-length footswitch along table base
- Absorption 0.9 mm al equivalent
- Heavy-duty grid cabinet
- Heavy-duty manual cassette tray
- 103 line, 10:1 ratio, 34-44" focal range grid
- The tabletop will support patients up to 300 kgs (661 lbs)
13-CSM/S225 Rotate Tube Stand with Transverse Travel • Floor to wall or Floor to ceiling mounted
- +/-5" Transverse travel
- 360° Column Rotation, mechanical detent
- Vertical travel 13.5"-76.8"
- 39.2" wall to focal spot at detent position • Platform tube mount (trunnion ring optional)
- Angulation dial
- Magnetic locks for longitudinal, transverse, vertical & tube rotation • Fits in ceiling heights of 93"-120"
- 75.7" Longitudinal Travel (8' floor track)
- UL Classified operates from 24 VDC
- Floor to wall mounted counterbalanced column
- Minimum ceiling height: 86" from floor
- Vertical travel: 9-3/4" to 72-3/4"
- Electric locks (24VDC 2 Amp required)
- Grid cabinet with heavy-duty tray
- 10:1, 103 line grid
- Operates on 120 VAC
Tube, 140,000HU, 1.0-2.0, 90 deg
Certified Manual Collimator with laser light, LED, 125kVP
25 ft HV Cables
SOLID 208 VAC or above power line required. For power lines BELOW 208 VAC, auxiliary boost transformer is required,
WARRANTY: FIVE YEARS ON PARTS. TUBE IS 1ST YEAR FULL, REMAINING FOUR YEARS ARE PRORATED.
Digital DR panel, Patient Image software, Computer, and Monitor not Included in price
Optional DR panel, Patient Image software, Computer, and Monitor
14 x 17 Wireless DR panel
17 x 17 Tethered DR panel
Maven Imaging Sample Urgent Care Room Layout
*This product has been permanently discontinued.
Replacement products available.