GP-10-LP Digital Dragon SPSLW4-LWD Portable 4.0/8.0 KW – MavenImaging
 

GP-10-LP Digital Dragon SPSLW4-LWD Portable 4.0/8.0 KW

Regular price $59,500.00 Sale

Product Details

GP-10-LP Digital Dragon SPSLW4-LWD Portable 4.0/8.0 KW

Portable System with Toshiba DR Panel and Laptop Computer

Dragon Portable System, 4.0 kW Lightweight with Toshiba DR Flat Panel

  • 40 to 125 kVp in 1 kVp steps
  • 125 kVp @32 mA, 100 kVp@40 mA, 50 kVp@80 mA, 40 kVp@ 100 mA
  • 14 mA Stations: 5, 6, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80 & 100
  • 0.001 - 10 Second exposure time range, 0.1-250 mAs
  • Allows customization of 6 APR regions (skull, thorax, spine, abdomen/pelvis, lower and upper extremities) - small, medium , large and pediatric patient sizes
  • 0.5mm - 1.8mm stationary anode x-ray tube, 47,215 kHU on 4kW unit
  • 0.6mm - 2.8mm stationary anode x-ray tube, 40,000 kHU on 8kW unit
  • Line Voltage: 110/220 VAC
  • Generator integration
  • Digital Kit to mount Portable Flat Panel
  • Foldable T-Shape Leg / Plastic Wheels
  • 360° Rotation of Tube Head
  • Power Cord 20 feet long, Exposure Cord 1O feet long
  • Stand on base with mechanical brakes on rear wheels
  • Front steering wheels and rear main transport wheels
  • 17.5" to 78.7" Vertical tube travel (44.5cm - 200cm)
  • Manual collimator with centering light and SID measuring tape
  • 147.7 pound total weight (with detector & accessories)
  • Line power detection system checks what incoming power is provided and once available power is determined, the exposure parameters are modified to accommodate the available power

          FDX3543RP

          Toshiba 14"x17" Tethered DR Panel

          • Active area 350 (H) x 43 (V)mm (14x17")
          • Cesium Iodide (Csl) with Amorphous Silicon (a-Si) photodiode
          • 2448 (H) x 2984 (V) Pixel Matrix; 143 micron Pixel Pitch
          • Short Cycle Time: Shot to Shot 6 sec.
          • Limiting Resolution: 3.7 Ip/mm typical
          • MTF (2.0lp/mm, 70kVp, 1x1) 36% typical; DOE >70%
          • 16 bit AID conversion; Energy Range: 40-150kVp
          • 4 mR / frame maximum entrance dose
          • Power Supply Unit
          • Sensor weight: 6.6 pounds (3kg)

          HC-ECOM

          lmagePlus Digital Acquisition System on Laptop Computer
          • Symphony Image Processing Software to improve image contrast, adjust dynamic range, enhance details and reduce noise, to produce the highest quality images
          • Generator Integration allowing the software to control the generator
          • Image Management (PACS, HIS/RIS)
          • DJCOM communication, full DICOM 3.0 Compatibility, DICOM worklist from HIS/RIS, store images through PACS network system, DICOM image print, DICOM MPPS

          OPTIONAL...: Wireless Detector in place of Tethered Detector,


              *This product has been permanently discontinued.

              Replacement products available.

              Product Reviews

              Shipping & Returns

              Shipping - Delivery shall be made at FOB shipping point of origin. Seller's responsibilities for the Equipment purchased pursuant hereto ceases and title and risk of loss passes to Customer upon delivery to the carrier. In the event of loss, damage, injury or destruction after such delivery to the carrier, claims must be made against the carrier and not against Seller. In no event shall any loss, damage, injury or destruction operate in any manner to release Customer from the obligation to make payments required herein. Returns - Unless a product is labeled "all sales final" at the time of purchase, all orders may be returned within 30 days for a refund. In order to return or exchange (under the guidelines described below) all or part of your order, customer must contact us for a Return Merchandise Authorization number (RMA#). Call toll free (800) 949-8015 to obtain RMA # from a Seller's representative. All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. with the authorization (RMA#) clearly printed on the outside of the package. Return requests must be made within 30 days of the receipt date. All returns must be certified to be in good condition by one of our engineers before refund can be accepted. If the product has been damaged, seller will assess the damage and will determine if the product is entitled to a refund. All free items must be returned together with purchased items in order to receive a refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levy a restocking fee of 25% of the cost of items returned. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied. Installation, training or professional services are NON-REFUNDABLE. Seller is responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal US Postal Service cannot be tracked to ensure delivery. Since Seller cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.
              Loading...