Product Details
- 25 kHz Constant Potential, 80 kW High Frequency (HF) generator
- Anatomical Programming
- kVp range: 40-150 in 1 kV steps
- mA Range: 10-1000 mA
- mAs range: 0.1-1000 mAs
- Operates from 3-phase, 400-480V electric service
- Pedestal Mount and Handswitch
- Dual Speed Starter
- AEC Logic
- 25 kHz Constant Potential, 65 kW High Frequency (HF) generator
- Anatomical Programming
- kVp range: 40-150 in 1 kV steps
- MA Range: 10-630 mA
- MAs range: 0.1-800 mAs
- Operates from 3-phase, 400-480V electric service
- Pedestal Mount and Handswitch
- Dual Speed Starter
- AEC Logic
- 25 kHz Constant Potential, 50 kW High Frequency (HF) generator
- Anatomical Programming
- kVp range: 40-150
- MA stations: 10-630
- MAs range: 0.1-630 mAs
- Operates 3-phase 230V or 400-480VC electric service (07287 required for 140kVp
- techniques and above for 208-229V, see below for pricing)***
- Pedestal Mount and Handswitch
- A selected transformer operates from 1-phase 240V (08326 transformers required for 208-229V electrical service, see below for pricing)
- 25 kHz Constant Potential, 40 kW High Frequency (HF) generator
- Anatomical Programming
- kVp range: 40-125/150, optional
- mA stations: 10-500
- mAs range: 0.1-630 mAs
- Operates from 1-phase 230V, 3-phase 230V, or 400-480VC electric service (07287
- required for 140kVp techniques and above for 208-229V, see below for pricing)
- Includes step-up transformer for voltages 208-229V (single-phase, only)
- Pedestal Mount and Handswitch
- 25 kHz Constant Potential, 32 kW High Frequency (HF) generator
- Anatomical Programming
- kVp range: 40-125
- MA stations: 10-400
- MAs range: 0.1-630 mAs
- Operates from 1-phase 208V-240VB, 3-phase 208-240V or 400-480V electric service
- Pedestal Mount and Handswitch
Specifications of the AMRAD® Medical S Series:
- Technique selections:
- 1) Anatomical Programming
- 2) kVp / mA / Time
- 3) kVp /mAs
- 4) kVp / AEC (optional)
- Remote Diagnostics – Conditions, apply. Does not apply to 510S
- LCD display of all technique factors ( mA, kVp, mAs) and messaging
- Automatic line compensation ±10 %.
- Maximum line regulation for maximum kVA demand: 6%.
- Self-diagnosis indicators identify malfunctions in the system.
- Intuitive error code indication for easy maintenance.
- Independent Heat Unit storage for X-ray Tube, even after turning On/Off the equipment
- X-ray tube overload protection
- 50 ft. console interconnect cable
- CSA, CE
Footnotes:
A Generators purchased as a loose component have a 1-year Parts Warranty
B For Single-Phase Generators of 32 kW at 208 V~, the maximum mA are limited to 160 when the selected kVp are within 126 and 134; to 125 mA when the selected kVp are 135 or 136; and to 100 mA when the selected kVp are higher than 136. See above 00530 for full range use
C For Three-Phase Generators from 40 to 50 kW at 208 V, the maximum mA are limited to 200 when the selected kVp are 140 or higher.
D For Single-Phase Generators of 50 kW at 230 V, the maximum mA are limited to 250 when the selected kVp are 140 or higher.