Chattanooga Revision Kit – MavenImaging
 

Chattanooga Revision Kit

Ensure the longevity and consistent performance of your radial pressure wave therapy system with the comprehensive Revision Kit. Designed specifically for the Mobile RPW unit, this all-in-one maintenance package provides everything required to overhaul the handpiece and restore it to...
Need a quote? Get an instant quote delivered to your email!
We value your privacy and will not sell your information to anyone.

Product Details

Ensure the longevity and consistent performance of your radial pressure wave therapy system with the comprehensive Revision Kit. Designed specifically for the Mobile RPW unit, this all-in-one maintenance package provides everything required to overhaul the handpiece and restore it to factory-standard functionality. Over time, the internal kinetic components of shockwave devices experience natural wear and tear, which can lead to fluctuations in energy output or reduced therapeutic efficacy. This kit eliminates those variables, offering a straightforward solution for preventative maintenance that minimizes device downtime and maximizes the return on your equipment investment. By replacing critical wear parts simultaneously, practitioners can guarantee reliable, high-energy delivery for every patient treatment, ensuring the mechanical precision necessary for effective rehabilitation.

Key Features and Benefits

This kit contains high-grade replacement parts engineered to withstand the rigorous demands of daily clinical use.

  • Two High-Performance Projectiles: The projectile is the core of the radial pressure wave generation. The kit includes two precision-machined projectiles designed to deliver consistent kinetic energy transfer to the transmitter. Regular replacement ensures that the shockwaves penetrate tissue effectively without energy loss.
  • Smooth Applicator Operation: With two new guide tubes included, the projectile creates a consistent, friction-free movement path. This results in stable frequency output and reduces mechanical noise or vibration during treatment.
  • Comprehensive Sealing System: The included sealing set protects the internal mechanism from moisture, dust, and debris. This maintains the hygiene of the device and prevents internal contamination that could compromise the pneumatic system.
  • Extended Device Lifespan: Proactive replacement of these consumable parts prevents damage to the more expensive components of the handpiece, effectively extending the operational life of your Mobile RPW unit.
  • Consistent Clinical Outcomes: By ensuring your equipment operates at factory specifications, you provide patients with reliable, reproducible treatment sessions, fostering trust and better recovery rates.
  • Two Precision Guide Tubes: Friction within the guide tube can significantly impact the performance of the projectile. These replacement tubes are manufactured to exact tolerances, ensuring smooth, unobstructed movement of the projectile for uniform shockwave generation and reduced mechanical noise.
  • Complete Sealing Set: Airtight integrity is vital for the pneumatic system to function correctly. The included sealing set rejuvenates the internal pressure chamber, preventing air leaks that could compromise the power of the shockwave or damage the internal mechanics of the handpiece.

Indications for Use

The Revision Kit is intended for the routine maintenance and refurbishment of the Mobile RPW handpiece. It is indicated for use in the following scenarios:

  • Routine Maintenance Intervals: To be installed after a set number of shocks (typically recommended between 1 million to 2 million pulses, depending on usage intensity) to prevent mechanical failure.
  • Performance Restoration: When the operator notices a decrease in power output, irregular frequency, or inconsistent shockwave delivery during therapy sessions.
  • Mechanical Overhaul: When the handpiece exhibits signs of wear, such as increased operational volume or internal friction, suggesting the projectile or guide tube has reached the end of its lifecycle.

Treatment Guidelines and Clinical Application

maintaining your equipment with this Revision Kit ensures that the Mobile RPW unit continues to support standard treatment guidelines for various musculoskeletal conditions. A well-maintained unit ensures:

  • Consistent Energy Density: Essential for treating chronic tendinopathies (e.g., plantar fasciitis, Achilles tendinopathy) where specific energy levels are required to stimulate tissue regeneration.
  • Reliable Frequency Control: Crucial for myofascial trigger point therapy, allowing the practitioner to adjust frequency accurately without mechanical lag.
  • Patient Safety and Comfort: Worn components can cause erratic pulsing or "spikes" in output. Installing the revision kit ensures a smooth, controlled application of energy, maintaining patient comfort levels throughout the procedure.

Specifications

  • Compatibility: Mobile RPW Unit Handpiece
  • Projectiles: 2 included
  • Guide Tubes: 2 included
  • Sealing Set: Complete set of replacement O-rings/seals
  • Manual: Step-by-step instructions for proper maintenance and use

Maintenance Tips

In addition to regular cleaning and disinfecting, there are a few simple maintenance tips that can help extend the life of your Mobile RPW Unit Handpiece:

  • Always follow recommended pressure settings and avoid using excessive force during treatment.
  • Use only approved projectiles and guide tubes to prevent damage to internal components.
  • Inspect O-rings and seals regularly and replace as needed to maintain proper sealing.
  • Store in a dry, clean environment when not in use.

Product Reviews

Shipping & Returns

Shipping - Delivery shall be made at FOB shipping point of origin. Seller's responsibilities for the Equipment purchased pursuant hereto ceases and title and risk of loss passes to Customer upon delivery to the carrier. In the event of loss, damage, injury or destruction after such delivery to the carrier, claims must be made against the carrier and not against Seller. In no event shall any loss, damage, injury or destruction operate in any manner to release Customer from the obligation to make payments required herein. Returns - Unless a product is labeled "all sales final" at the time of purchase, all orders may be returned within 30 days for a refund. In order to return or exchange (under the guidelines described below) all or part of your order, customer must contact us for a Return Merchandise Authorization number (RMA#). Call toll free (800) 949-8015 to obtain RMA # from a Seller's representative. All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. with the authorization (RMA#) clearly printed on the outside of the package. Return requests must be made within 30 days of the receipt date. All returns must be certified to be in good condition by one of our engineers before refund can be accepted. If the product has been damaged, seller will assess the damage and will determine if the product is entitled to a refund. All free items must be returned together with purchased items in order to receive a refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levy a restocking fee of 25% of the cost of items returned. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied. Installation, training or professional services are NON-REFUNDABLE. Seller is responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal US Postal Service cannot be tracked to ensure delivery. Since Seller cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.
Loading...

Your cart